Bottom door

In TavanTak products, two types of top doors are used:

1- Top door made of aluminum

2- Top door made of cast iron

The upper door itself consists of two holes that are used to enter the cable and the cable grip rubber, and the other hole is used to enter the float cable when the pump is floating, and in the normal case, the pump is without float. It is used to test the ventilation of the upper door, which is closed with 6 brass screws and the corresponding o-ring and sealed by a plastic cap, and should not be manipulated in any way unless opened and closed by the responsible persons or by the company itself (for sealing). )

To open and close the top door, the following tools are needed:

Wrench – Fiber hammer – Wrench 4 and 5 and to test the capacitor of digital multimeter and ohmmeter

After introducing the tools, we will discuss how to open the top door and introduce the different parts of the door and the safety tips of the top door.

Before opening the top door, make sure that the pump is used or new. If the pump is used, there is a possibility that air will collect inside the door, and for this reason, first open the 4 brass nuts halfway with a wrench and hammer. Release the fiber of the door a little so that the air inside the door is evacuated and there is no danger, and we continue to open the door again.

After opening the door, in the first stage of the cable wash test, there is a screw cap that is not broken or has not been opened, which causes the wires to protrude and cause a connection.

After opening the door, in the first stage of the cable wash test, there is a screw cap that is not broken or has not been opened, which causes the wires to protrude and cause a connection.

The third step is to test the cable grip, which is made of ultramid material that does not deform in the face of heat and pressure, and is fastened to the top door with 3 6 * 15 Allen screws, and tests the screws with a wrench that has not been opened. To be.

The fourth step is to test the three-hole clamp, which is closed in place by 3 5 * 10 Allen screws, and with a wrench, check that they are not open and that the three-hole clamp itself is not broken.

Step 5 Remove the lower door o-ring and check for corrosion – double-sided or injured, and then lubricate the o-ring and put it in place, and finally after testing all the steps of the cable washers in place Place the wires in the middle of the lower door and place the upper door on the lower door. Make sure that when closing the door, none of the wires are between the two doors, which will cause a connection, and then with a few hammer blows. We put the fiber of the door in its place and close and tighten the cap nuts with the corresponding spring washer in place, and after the door is tightened by the ohmmeter device, we test the power lines of the pump that are not connected.

Top door2

In TavanTak products, two types of top doors are used:

1- Top door made of aluminum

2- Top door made of cast iron

The upper door itself consists of two holes that are used to enter the cable and the cable grip rubber, and the other hole is used to enter the float cable when the pump is floating, and in the normal case, the pump is without float. It is used to test the ventilation of the upper door, which is closed with 6 brass screws and the corresponding o-ring and sealed by a plastic cap, and should not be manipulated in any way unless opened and closed by the responsible persons or by the company itself (for sealing). )

To open and close the top door, the following tools are needed:

Wrench – Fiber hammer – Wrench 4 and 5 and to test the capacitor of digital multimeter and ohmmeter

After introducing the tools, we will discuss how to open the top door and introduce the different parts of the door and the safety tips of the top door.

Before opening the top door, make sure that the pump is used or new. If the pump is used, there is a possibility that air will collect inside the door, and for this reason, first open the 4 brass nuts halfway with a wrench and hammer. Release the fiber of the door a little so that the air inside the door is evacuated and there is no danger, and we continue to open the door again.

After opening the door, in the first stage of the cable wash test, there is a screw cap that is not broken or has not been opened, which causes the wires to protrude and cause a connection.

After opening the door, in the first stage of the cable wash test, there is a screw cap that is not broken or has not been opened, which causes the wires to protrude and cause a connection.

The third step is to test the cable grip, which is made of ultramid material that does not deform in the face of heat and pressure, and is fastened to the top door with 3 6 * 15 Allen screws, and tests the screws with a wrench that has not been opened. To be.

The fourth step is to test the three-hole clamp, which is closed in place by 3 5 * 10 Allen screws, and with a wrench, check that they are not open and that the three-hole clamp itself is not broken.

Step 5 Remove the lower door o-ring and check for corrosion – double-sided or injured, and then lubricate the o-ring and put it in place, and finally after testing all the steps of the cable washers in place Place the wires in the middle of the lower door and place the upper door on the lower door. Make sure that when closing the door, none of the wires are between the two doors, which will cause a connection, and then with a few hammer blows. We put the fiber of the door in its place and close and tighten the cap nuts with the corresponding spring washer in place, and after the door is tightened by the ohmmeter device, we test the power lines of the pump that are not connected.

Top door

In TavanTak products, two types of top doors are used:

1- Top door made of aluminum

2- Top door made of cast iron

The upper door itself consists of two holes that are used to enter the cable and the cable grip rubber, and the other hole is used to enter the float cable when the pump is floating, and in the normal case, the pump is without float. It is used to test the ventilation of the upper door, which is closed with 6 brass screws and the corresponding o-ring and sealed by a plastic cap, and should not be manipulated in any way unless opened and closed by the responsible persons or by the company itself (for sealing). )

To open and close the top door, the following tools are needed:

Wrench – Fiber hammer – Wrench 4 and 5 and to test the capacitor of digital multimeter and ohmmeter

After introducing the tools, we will discuss how to open the top door and introduce the different parts of the door and the safety tips of the top door.

Before opening the top door, make sure that the pump is used or new. If the pump is used, there is a possibility that air will collect inside the door, and for this reason, first open the 4 brass nuts halfway with a wrench and hammer. Release the fiber of the door a little so that the air inside the door is evacuated and there is no danger, and we continue to open the door again.

After opening the door, in the first stage of the cable wash test, there is a screw cap that is not broken or has not been opened, which causes the wires to protrude and cause a connection.

After opening the door, in the first stage of the cable wash test, there is a screw cap that is not broken or has not been opened, which causes the wires to protrude and cause a connection.

The third step is to test the cable grip, which is made of ultramid material that does not deform in the face of heat and pressure, and is fastened to the top door with 3 6 * 15 Allen screws, and tests the screws with a wrench that has not been opened. To be.

The fourth step is to test the three-hole clamp, which is closed in place by 3 5 * 10 Allen screws, and with a wrench, check that they are not open and that the three-hole clamp itself is not broken.

Step 5 Remove the lower door o-ring and check for corrosion – double-sided or injured, and then lubricate the o-ring and put it in place, and finally after testing all the steps of the cable washers in place Place the wires in the middle of the lower door and place the upper door on the lower door. Make sure that when closing the door, none of the wires are between the two doors, which will cause a connection, and then with a few hammer blows. We put the fiber of the door in its place and close and tighten the cap nuts with the corresponding spring washer in place, and after the door is tightened by the ohmmeter device, we test the power lines of the pump that are not connected.